Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Rev. bras. oftalmol ; 78(6): 406-408, nov.-dez. 2019. graf
Article in English | LILACS | ID: biblio-1057922

ABSTRACT

Abstract Choroidal melanomas are the most common primary intraocular malignant tumor in adults. They tend to be more malignant; because of their location hidden behind the iris they can not be detected until they become larger. Therapeutic strategy is related by size, extension, number and location of tumor and growth patterns. High frequency ultrasound biomicroscopy (UBM) gives high resolution, cross-sectional images of the anterior segment lesions. Postequatorial lesions and intracranial extension of the melanomas are scanned by magnetic resonance imaging (MRI). We report a case of bilobed tumor with confusing appereance in preoperative imaging studies and macroscopy following enucleation. MRI is the perfect imaging method to reveal extension and size of the tumor in the posterior chamber. Combined use of UBM and MRI provides appropriate staging of ocular melanomas.


Resumo Melanomas coroidais são os tumores malignos intra-oculares primários mais comuns em adultos. Eles tendem a ser mais malignos; devido à sua localização ser escondida por detrás da íris eles não podem ser detectados até se tornarem maiores. A estratégia terapêutica está relacionada com tamanho, extensão, número e localização dos padrões tumorais e de crescimento. O biomicroscopio ultra-sónico de alta frequência (BMU) fornece imagens transversais de alta resolução das lesões do segmento anterior. Lesões pós-equatoriais e de extensão intracraniana dos melanomas são digitalizadas em ressonância magnética (RM). Relatamos um caso de tumor com dois lóbulos, com aparência confusa em exames de imagem pré-operatórios e macroscopia após enucleação. A RM é o método de imagem perfeito para revelar a extensão e o tamanho do tumor na câmara posterior. O uso combinado de BMU e MRI fornece o faseamento apropriado dos melanomas oculares.


Subject(s)
Humans , Male , Aged, 80 and over , Ciliary Body/pathology , Neoplasm Staging , Melanoma/diagnosis
2.
Arq. bras. oftalmol ; 73(2): 171-174, Mar.-Apr. 2010. tab
Article in Portuguese | LILACS | ID: lil-548149

ABSTRACT

OBJETIVO: Avaliar os resultados visuais e investigar, através da biomicroscopia ultrassônica, o posicionamento das lentes intraoculares e do anel endocapsular em 17 olhos de 10 portadores de subluxação congênita do cristalino, submetidos à mesma técnica cirúrgica pelo mesmo cirurgião. MÉTODOS: O estudo foi realizado no Hospital de Olhos de Pernambuco e Fundação Altino Ventura. A técnica cirúrgica consistiu em facoaspiração com implante de anel endocapsular e de lentes intraoculares com amputação de uma das alças. A idade variou entre 7 e 22 anos. Foram coletados dados sobre acuidade visual para longe pré e pós-operatória, tempo de seguimento após a cirurgia e complicações. Os pacientes foram submetidos à biomicroscopia ultrassônica. RESULTADOS: O tempo de seguimento médio foi de 2,8 anos. Houve melhora da acuidade visual para longe nos 17 (100 por cento) olhos: 12 olhos (70,6 por cento) apresentaram acuidade visual para longe melhor que 20/40; 4 (23,5 por cento) apresentaram acuidade visual para longe entre 20/40 e 20/100 e 1 (5,9 por cento) apresentou acuidade visual para longe pior que 20/100, porém melhor que acuidade visual para longe pré-operatória. A opacificação da cápsula posterior ocorreu em 10 olhos (58,9 por cento). Na biomicroscopia ultrassônica observou-se que todas as lentes intraoculares estavam parcialmente descentralizadas, contudo sem atingir o bordo pupilar. Em todos os casos observou-se um adequado posicionamento do anel e um bom suporte capsular. CONCLUSÃO É possível concluir que o tratamento cirúrgico avaliado proporciona uma boa centralização das lentes intraoculares e do anel endocapsular, com melhora da acuidade visual para longe, sendo uma opção viável, eficaz e segura na reabilitação visual dos pacientes com subluxação congênita do cristalino.


PURPOSE: To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. METHODS: The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. RESULTS: The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100 percent) eyes: in 12 eyes (70.6 percent) the visual acuity was better than 20/40; 4 (23.5 percent) ranged from 20/40 to 20/100, and 1 (5.9 percent) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9 percent). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. CONCLUSION: The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.


Subject(s)
Adolescent , Child , Female , Humans , Young Adult , Ectopia Lentis/surgery , Lens Implantation, Intraocular/methods , Visual Acuity , Follow-Up Studies , Microscopy, Acoustic , Prospective Studies , Treatment Outcome , Young Adult
3.
Rev. bras. oftalmol ; 68(1): 18-21, Jan.-Feb. 2009. tab
Article in Portuguese | LILACS | ID: lil-508920

ABSTRACT

OBJETIVO: Verificar a influência de alguns tipos de opacidade lenticular no teste da tela de Amsler entre portadores de catarata senil. MÉTODOS:Foram avaliados 200 pacientes portadores de catarata senil através da aplicação da tela de Amsler, antes e após a cirurgia. O estudo foi feito em um único centro, simples cego, randomizado e prospectivo. Os pacientes foram submetidos a exame de acuidade visual (AV) corrigida, para longe e perto, biomicroscopia do segmento anterior e da região macular. RESULTADOS:A acuidade visual média pré-operatória para longe dos 200 pacientes foi de 0,5 logMAR (20/60 Tabela de Snellen). Após a cirurgia, dos 11 pacientes que haviam apresentado alteração na tela de Amsler pré-operatória, dez não tiveram alteração no exame de reavaliação da tela. Os 10 indivíduos apresentaram acuidade visual pós-operatória, com a melhor correção óptica, para distância de 20/20 e para perto de J1. No presente estudo foi constatado 5,5 por cento com alteração na tela de Amsler antes da cirurgia, em 5 por cento dos pacientes estas alterações estavam diretamente relacionados a opacidade do cristalino e 0,5 por cento relacionados a opacidade vítrea. CONCLUSÃO: Conclui-se que a alteração no exame da tela de Amsler pode ser diretamente relacionada à catarata, na ausência de alterações maculares clínicas.


PURPOSE: To assess the influence of some forms of lenticular opacification in the Amsler grid test among patients suffering from senile cataract. METHODS: Randomized, prospective interventional trial. Two hundred patients with senile cataract were evaluated with Amsler grid, measurement of best corrected visual acuity for near distance and far distance, biomicroscopy of the anterior segment and macular region. RESULTS: With a two months minimum of follow-up, the average visual acuity after surgery for far distance among the 200 patients was 0.48 logMAR, 11 (5.5 percent) had changes in the Amsler grid test before surgery. After surgery, from the 11 subjects with changes in the preoperative Amsler grid test, 10 had no more changes in the Amsler grid. These 10 subjects had postoperative best corrected visual acuity of 20/20, and Jaeger 1, no abnormalities of the fundus having been detected. Under this study conditions, the prevalence of changes in the Amsler grid test was 5.5 percent, and in 5 percent of the patients these changes were likely related to cataract whereas in 0.5 percent they were related to vitreous opacification. CONCLUSION: Some patient with cataract showed changes in the Amsler grid test that can be directly related to cataract, in the absence of clinically detected macular disorders.

SELECTION OF CITATIONS
SEARCH DETAIL